FDNP 44

FDNP 44

The Amfah portable professional dehumidifiers of the series FDNP are high-performance appliances, equipped with robust galvanized steel frame coated with epoxy resins and mounted on 2 big wheels that make it easy to move even in yard environments or in case of obstacles. They have a high efficiency air filter in polyurethane, washable and easily replaceable, and a very large condensate collection tank with the possibility of direct drain. It is possible to install a condensate lifting pump instead of the collection tank, allowing condensate pumping up to a height of 3.5 meters from the machine positioning level.

Have Any Questions?
Call Us Today

+91-8080161161

info.india@amfah.com

FEATURES AND FUNCTIONS

FRAME

The frame and the sheets are hot galvanised, epoxy powder coated, ensuring high strength and durability.

COMPRESSOR

Rotative compressor, mounted on vibration dampers.

REFRIGERANT CIRCUIT

Evaporator: the evaporation coil consists of smooth tubes in aluminium. The smooth tubes ensure a high yield of the dehumidifier, significantly reducing energy consumption, even at low relative humidity.

Condenser: the coil is made of copper pipes and aluminium fins, the wide size of the condenser fins ensures resistance to dust, long life and easy maintenance of the machine.

CONDENSATE COLLECTION TANK

The condensate collection tank, installed as standard, is very large and can be easily removed. The machine is also ready for connection to a fixed condensate drain.

CONDENSATE LIFTING PUMP

Optional in all versions, it replaces the condensate collection tank and allows to remove the condensed water up to a height of 3.5 mt with respect to the position of the machine. Equipped with an alarm for dehumidifier stop in the case of pump failure.

Alternatively, it is available a condensate lifting pump kit, easily applicable outside the dehumidifier, provided with malfunction alarm that switches off the machine.

FAN

Axial fan, statically and dynamically balanced, long-lasting and durable.

MICROPROCESSOR

Controls the defrosting cycles with hot gas, the timer of the compressor and the alarm card.

CONTROL PANEL

Located at the top of the machine.

Executed according to the European standards in force.

TESTING

Tests are performed to check the tightness of the refrigeration circuit. Electrical discharge tests and functional tests are performed as well.

Have Any Questions?
Call Us Today

+91-8080161161

info.india@amfah.com

Enquiry Form

Please enable JavaScript in your browser to complete this form.